Setup
The controller always starts on the last configured
settings, or on the factory defaults if you are
setting up for the first time or have performed a
Restore Factory Defaults. This setup is saved
in the equipment memory, even when power is
removed. The controller is set up by using the system
parameters and configuration screens. These values
can be adjusted and requested manually or through
the discrete I/O interface.
1. Press on to turn on the controller.
2. To access the Setup Screens, press and hold
for 5 seconds from any Run Screen. Press
buttons T1/T2 to move between Setup Screens
0-7 (Parameters).
NOTE: Press
to access Setup Screens 8–11
(Configuration). Press buttons T1/T2 to move
between Screens 8–11. To return to Setup
Screen 1, press
again.
3. To return to the Run Screens, press
from any
Setup Screen.
This table summarizes the system parameters
(P00–P07) that are defined using Setup Screens 0–7.
The table also shows the configurations (C0–C3) that
are defined using Setup Screens 8–11. Each Setup
Screen is then described in detail in the sections that
follow the table.
PARAMETERS
Setup
Screen
Display
(A1)
Value
Description
Display (A3) Values
Display
(A4)
Value
0
P00
Applicator Type
Display A2: APP
Use to define applicator type and features. This
selection is set in the factory and cannot be
changed. This selection is not overwritten if a
Factory Default Reset is performed.
0: Standard
(solventborne)
1: Waterborne
Std
UUb
1
P01
Electrostatic Control Mode
Display A2: Ctrl
Define how electrostatics generation is controlled.
This selection is set to 1 (current) in the factory
and cannot be changed.
1: Current Control
CUrr
2
P02
Remote Interface
Display A2: bUS
Use to designate the remote interface from which
the controller will accept commands. For this
version of the controller, the CAN selection is
active, but no Graco CAN device is available.
0: Off
1: Discrete I/O (default)
2: CAN
oFF
dio
CAn
3
P03
Analog Input Type
Display A2: Ai
Use to designate the input signal type for the
discrete I/O analog inputs.
0: Voltage(default)
1: Current
Volt
CUrr
4
P04
Analog Output Type
Display A2: Ao
Use to designate the output signal type for the
discrete I/O analog output.
0: Voltage (default)
1: Current
Volt
CUrr
333266D