Setup Screen 10
Use Setup Screen 10 (Configuration C2) to select the
time (in seconds) from when the electrostatics are
disabled until the electrostatic voltage is discharged.
Press buttons T3/T4 to change the setting. For most
solventborne systems, this setting can remain at 0.0,
as no discharge time is needed for a solventborne
system.
In a waterborne system, set the discharge timer to
a value that will ensure that the system has been
discharged. Verify that the system is discharged
using the Fluid Voltage Discharge and Grounding
Procedure in gun manual 332992.
• Range is 0.0 – 60.0 by 0.1
• Solventborne default is 0.0 (shown)
• Waterborne default is 30.0 (not shown)
Setup Screen 11
Use Setup Screen 11 (Configuration C3) to set the
interval of transition time (in seconds) from zero to
charge or between electrostatic set points from one
Preset to another. This setting will help eliminate
nuisance arc detection errors during transition time.
This setting may be required depending on arc
detection settings.
• Range is 0.0 – 5.0 sec
• Default is 0.0 (shown)