Pin
Type
Description
6
Digital Output
Safe-to-Move Output
Use to signal whether the applicator can be moved out of SAFE POSITION. This
output is tied to the arc detection blanking time setting on Setup Screen 9. The
blanking timer begins counting down when high voltage is enabled. When the timer
has reached zero, the Safe-to-Move Output is switched from 0 to 1.
0: Applicator must not be moved out of SAFE POSITION because arc detection
is blanked and electrostatics are turned on.
1: Applicator allowed to be moved out of SAFE POSITION because arc
detection is effective or electrostatics are turned off.
7
Digital Output
Error Output
Use to signal detection of an error condition.
0: No error condition detected.
1: An error condition has been detected and reported.
NOTE: Reset by Error Reset input or by local confirmation.
8
Ground
I/O Ground
Reference potential for I/O interface signals.
9
Analog Input
Current Setpoint Input
Use to set the current setpoint (µA) nominal value. The REMOTE current setpoint
input applies when Preset 0 (P000) is selected and the controller is in REMOTE
operation.
The input voltage or current is used to create a relational output current value for
the gun electrostatics power supply. The larger the input value, the greater the
electrostatics current setpoint.
0 – 10V (received input) ➔ 0 – 150µA (desired gun output)
OR
4 – 20mA (received input) ➔ 0 – 150µA (desired gun output)
The type of input is selected on
10
Analog Input
Voltage Setpoint Input
Use to set the voltage setpoint (kV) nominal value. The REMOTE voltage setpoint
input applies when Preset 0 (P000) is selected and the controller is in REMOTE
operation.
The input voltage or current is used to create a relational output voltage value for
the gun electrostatics power supply. The larger the input value, the greater the
electrostatics voltage at the gun.
0 – 10V (received input) ➔ 0 – max kV* (desired gun output)
OR
4 – 20mA (received input) ➔ 0 – max kV* (desired gun output)
The type of input is selected on
* max kV = 100 kV (solventborne) or 60 kV (waterborne)
20