Run Screen 3
Run Screen 3 is the maintenance screen. This
screen shows the 4 maintenance counters and the
non-resettable trigger counter.
When dashes are shown in the maintenance
counters, monitoring is deactivated. When numbers
are shown, the maintenance counters show days of
remaining service life.
NOTE: Maintenance counters are activated only
when electrostatics are active/triggered.
NOTE: The trigger counter shows an amount of time
(in days) that electrostatics have been turned on for
the connected power supply. It cannot be cleared.
Each tenth equates to 2.4 hours of elapsed time.
To activate monitoring: press the corresponding
and
simultaneously for a deactivated counter.
During the first activation a value of 1 is shown
as the start value. If monitoring has already been
activated at some earlier point, then the last stored
value is displayed. Set the desired service life for
each wearing part using the
and
.
To deactivate monitoring: press the corresponding
and
simultaneously for an active counter.
If the selected service life is exceeded, the
maintenance counter will be shown as a negative
number. The service symbol also will appear.
Controller operations are not stopped.
NOTE: Maintenance counters, states
(active/inactive), and set points are not reset
when factory defaults are restored.
Designation
Function
Units
Range
A1–A4
Maintenance counter 1–4
days
0.1–500
A5
Trigger counter, error diagnosis, or status
days
—
42
333266D