GEF & GEF-VH Series Fryers
Pre-Operation Checkout
33
4.4
Filter Pump Test
1. Follow steps in
Section 4-1
.
2. Place the Power Switch
①
in the
[ON]
position. Wait until Controller powers-up,
then press
[ALARM]
key to silence alarm.
3. Open Cabinet Door.
Disconnect and
remove Filter Pan if not done previously
.
4. Firmly press the palm of the hand over the
Filter Pan Quick Disconnect
②
fitting.
5. While covering the opening with the hand, set
the Pump Switch
③
to the
[FILTER PUMP]
position. The pump will start ... if suction is
felt, it is operating correctly. Return switch to
[OFF].
Allow pump to run
ONLY
long enough to
check for suction.
If no suction is felt, or if air seems to be
blowing out of the fitting, refer to the
troubleshooting procedures in
Section 8.2
,
otherwise see
Section 4.5
.
4.5
Perform Boil-Out Procedure
The following test confirms that the Filter Pump is operating properly.
Perform a Boil-Out Procedure to remove any dirt/debris that may have accumulated during shipment, or residue
remaining from manufacturing processes. See
Section 6.1, Boil-Out Procedure
. After the Boil Out procedure see
Section 4.6
.