9
GEF & GEF-VH Series Fryers
Installation
2.4.1
Conduit Routing
2.4
Electrical Connections
1. As needed, install appropriate sized circuit breaker in main electrical panel. See
Table 2.3
.
2. Connect 1-1/4” flexible conduit from main electrical panel to the Fryer. Attach conduit to rear of the Fryer
with appropriate conduit fittings. Allow enough length so that the Fryer can be moved easily for cleaning and
servicing. See
Figure 2.4.1
.
3. Open Fryer Cabinet Door and remove Service Entrance Box Cover. See
Figure 2.4.2
.
4. Route appropriately sized power wires from the circuit breaker in the main panel through the wire run inside
Cabinet wall to the front Service Box.
5. Connect power wires to the appropriate Terminal Blocks in the Service Entrance Box. See
Figure 2.4.2
.
6. Reinstall Service Entrance Box Cover and close the cabinet door.
1-1/4” Straight or 90°
Connector
1-1/4” Flexible
Conduit
Main Electrical
Panel
NOTE:
Electrical installation materials (breakers, conduit, fittings, wire, etc.) and installation labor shall be supplied by
the customer. Work should be performed by a qualified electrician, or service technician.
Installation must comply with local code requirements. Giles is not responsible for code compliance with regard
to installation and use of this appliance.
Summary of Contents for GEF-400
Page 2: ......
Page 7: ...vi ...
Page 35: ...24 GEF GEF VH Series Fryers Overview 3 5 Ventless Hood VH Model Only 2 3 8 6 5 7 4 1 ...
Page 41: ...30 GEF GEF VH Series Fryers Overview Notes ...
Page 79: ...68 GEF GEF VH Series Fryers Cleaning ...
Page 113: ...102 GEF GEF VH Series Fryers Parts List Notes ...
Page 114: ......