62
Fryer Operation
EOF SERIES FRYERS
5.1.8.
User Settings - Accessing & Editing
Press the
TIME
key
+
9 9 9 9
+
Use numeric keypad
[4] - [6]
(left/right) to scroll through list until
desired Setting is shown on the
Upper OLED Display
.
To exit the
USER SETTINGS
menu, press the
[CLEAR]
key.
To edit the setting press the
[EDIT]
key. Use numeric keypad
[2] - [8]
(up/down) to change the value. Press
[EDIT]
again to
save the new value.
Press the
START
key
NOTE:
The message
TOO LOW
or
TOO
HIGH
will be displayed if a value
being entered is outside the
allowable range and would cause
a Controller error for the current
state of the Fryer.
NAME
DESCRIPTION
RANGE
DEFAULT
TEMP SCALE
Temperature scale
°F or °C
°F
FORCE FILTER
When
ON
, forces user to filter oil after the specified number of
cook cycles are complete ... locks-out Fryer.
ON - OFF
ON
FORCE FILTER
SNOOZE
Allows (1) more cook cycle after FORCE FILTER count exceeded
when FORCE FILTER = ON.
ON -OFF
OFF
FILTER COUNT
Number of cook cycles before user is required to filter.
1 to 20
4
GUARD BAND
Cooking not allowed if oil temperature is outside of the
setpoint by amount of guard band
1 to 990
900
MAX SETPOINT
Maximum oil setpoint allowed.
32°F to 350°F
350°
AUTOCOOL
After a specified amount of time, unit will go into COOL mode. ON - OFF
OFF
AUTOCOOL TIME
(MINUTES)
If
AUTOCOOL
is
ON
, then after fryer is idle for the amount of
time specified here, the unit will go into
COOL
mode.
1 to 510 minutes
30
AUDIBLE ALARM
(SECONDS)
Duration of the audible alarm in seconds.
5 to 120 seconds
10
COOL TEMP
Temperature of the
COOL
mode
200°F to 350°F
275°F
BOIL TEMP
Temperature of the
BOIL OUT
mode
185°F to 208°F
200°F
FILTER RESET
Temperature that allows exiting of filter mode
200°F to 325°F
290°F
BOIL OUT TIME
Time (in minutes) for
BOIL OUT
mode
1 to 45 minutes
30
STIR ALARM
ENABLE
If enabled, allows the stir alarm to come on during a cook cycle. ON - OFF
ON
STIR ALARM %
When
STIR ALARM
is
ON
, the alarm will sound after this % of
the cooking cycle is complete.
10% to 90%
62%
KEY BEEP ENABLE If enabled, audible sound generated with each key press.
ON - OFF
OFF
LANGUAGE
Sets the Controller language
English-Spanish-
French
English
Summary of Contents for EOF Series
Page 2: ......
Page 4: ......
Page 8: ...vi Table Of Contents EOF SERIES FRYERS Notes ...
Page 16: ...4 Introduction EOF SERIES FRYERS ...
Page 22: ...10 Installation EOF SERIES FRYERS ...
Page 30: ...Overview 18 3 4 Control Panel EOF 20 EOF 24 6 5 4 3 2 1 7 EOF SERIES FRYERS 8 9 3 1 3 2 ...
Page 32: ...20 Overview 3 5 Control Panel FFLT Dump Station 1 EOF SERIES FRYERS ...
Page 36: ...24 Overview EOF SERIES FRYERS 3 7 Lower Cabinet EOF 20 EOF 24 2 1 1 2 EOF 24 EOF 20 ...
Page 38: ...26 Overview EOF SERIES FRYERS 2 1 3 8 FFLT Dump Station ...
Page 40: ...28 Overview EOF SERIES FRYERS 1 2 3 4 5 6 3 9 FFLT Lower Cabinet Filter Pan ...
Page 42: ...30 Overview EOF SERIES FRYERS 5 6 3 2 1 4 3 3 10 Filter Pan Assembly Detail ...
Page 100: ...88 Troubleshooting EOF SERIES FRYERS NOTES ...
Page 112: ...100 Parts List EOF SERIES FRYERS Not shown 1 3 2 5 4 7 6 8 8 7 EOF 20 Front Lower Cabinet ...
Page 118: ...106 Parts List EOF SERIES FRYERS Not shown 2 3 4 6 1 5 2 8 10 EOF 24 Rear Lower Cabinet ...
Page 120: ...108 Parts List EOF SERIES FRYERS 1 3 4 5 7 8 2 6 8 11 FFLT Cabinet Front ...
Page 122: ...110 Parts List EOF SERIES FRYERS 2 1 Not shown 4 3 8 12 FFLT Cabinet Rear ...
Page 126: ...114 Parts List EOF SERIES FRYERS Notes ...
Page 127: ......