65
Fryer Operation
EOF SERIES FRYERS
NOTE: If an error condition cannot be resolved, please contact a factory-authorized service agent, or call
800.554.4537 for Giles Technical Support.
5.1.11.1 Resolving Controller Errors and Alarms
●
DRAIN OPEN (Error Code OPEN) -
If the pot Drain Valve is open (even slightly) while Fryer power is
ON,
an
alarm tone sounds, 7-Segment Display shows
OPEn,
and the OLED Display reads
“ERROR ALARM - DRAIN IS
OPEN”.
If the Basket Lift is down, it will be raised. Heating Elements are disabled as long as the condition
exists.
Press the
[ALARM]
key to silence alarm tone. Completely close the Drain Valve to clear the error. When error
is cleared, alarm tone sounds again and the OLED Display reads
“CHECK OIL LEVEL, ENSURE VAT IS FULL, IF FULL
THEN PRESS [START]”.
This is a post-error alarm to alert user to confirm that cooking oil in the pot is still at the
FULL
level. Add oil if needed, then press the
[START]
key to return to
PREHEAT
mode.
●
MAX. ELEMENT TEMP (Error Code 19) -
Heating Element has exceeded the maximum temperature allowed by
the Controller. The alarm tone sounds, 7-Segment Display shows
Er19,
and the OLED Display shows
“ERROR
ALARM - MAX ELEMENT TEMPERATURE”.
Heating Element is automatically turned
OFF.
It must cool to an
acceptable temperature to clear the error. Typical cause of this error is low oil level, which has exposed the
heating element. It is possible for a false alarm to occur when preheating cold oil at the initial startup of a new
day. Vigorously stirring oil during preheat will usually prevent, or clear, a false alarm of this type.
●
MAX ELEMENT TEMP Post-error Warning (Error Code 07)
- After
Error 19
is cleared, a warning alarm occurs.
The 7-Segment Display shows
Er07,
and the OLED Display reads
“MAX ELEMENT TEMP - PRESS [START]”.
This
alarm alerts user that a maximum element temperature error occurred and is now cleared. Press
[START]
key
to enter
PREHEAT
mode. Heating Element will not turn
ON
until
[START]
is pressed.
●
BAFFLE FILTER MISSING (Error Code 21 - N/A
●
CHARCOAL FILTER MISSING (Error Code 22 - N/A
●
CLOGGED FILTER (Error Code 23 - N/A
●
E.A.C. DIRTY (Error Code 24 - N/A
Summary of Contents for EOF Series
Page 2: ......
Page 4: ......
Page 8: ...vi Table Of Contents EOF SERIES FRYERS Notes ...
Page 16: ...4 Introduction EOF SERIES FRYERS ...
Page 22: ...10 Installation EOF SERIES FRYERS ...
Page 30: ...Overview 18 3 4 Control Panel EOF 20 EOF 24 6 5 4 3 2 1 7 EOF SERIES FRYERS 8 9 3 1 3 2 ...
Page 32: ...20 Overview 3 5 Control Panel FFLT Dump Station 1 EOF SERIES FRYERS ...
Page 36: ...24 Overview EOF SERIES FRYERS 3 7 Lower Cabinet EOF 20 EOF 24 2 1 1 2 EOF 24 EOF 20 ...
Page 38: ...26 Overview EOF SERIES FRYERS 2 1 3 8 FFLT Dump Station ...
Page 40: ...28 Overview EOF SERIES FRYERS 1 2 3 4 5 6 3 9 FFLT Lower Cabinet Filter Pan ...
Page 42: ...30 Overview EOF SERIES FRYERS 5 6 3 2 1 4 3 3 10 Filter Pan Assembly Detail ...
Page 100: ...88 Troubleshooting EOF SERIES FRYERS NOTES ...
Page 112: ...100 Parts List EOF SERIES FRYERS Not shown 1 3 2 5 4 7 6 8 8 7 EOF 20 Front Lower Cabinet ...
Page 118: ...106 Parts List EOF SERIES FRYERS Not shown 2 3 4 6 1 5 2 8 10 EOF 24 Rear Lower Cabinet ...
Page 120: ...108 Parts List EOF SERIES FRYERS 1 3 4 5 7 8 2 6 8 11 FFLT Cabinet Front ...
Page 122: ...110 Parts List EOF SERIES FRYERS 2 1 Not shown 4 3 8 12 FFLT Cabinet Rear ...
Page 126: ...114 Parts List EOF SERIES FRYERS Notes ...
Page 127: ......