c. Return to the first screw and tighten it completely.
4.If the PHM slips off the blue retention clips when the screws are partially tightened,
follow these steps to secure the PHM:
a. Loosen both the heat sink screws completely.
b. Lower the PHM on to the blue retention clips, following the procedure described
in step 2.
c. Secure the PHM to the system board, following the replacement instructions
listed in this step above.
N
OTE
:
The processor and heat sink module retention screws should not be
tightened to more than 0.13 kgf-m (1.35N.m or 12 in-lbf).
After installing the Processor Heat Sink Module follow the procedure listed in
Removing the Processor from the Processor and Heat Sink Module
N
OTE
:
Only remove the processor from the processor and heat sink module if you
are replacing the processor or heat sink. This procedure is not required when
replacing a system board.
l
Follow the safety guidelines listed in
l
Follow the procedure listed in
Before working inside your system
l
Remove the air shroud.
l
Remove the processor and heat sink module.
Follow the below steps to remove a Processor from a Processor and Heat Sink module:
Contents
43