Follow the below steps to remove the Power Supply Unit blank:
If you are installing a second power supply unit, remove the power supply unit blank in
the bay by pulling the blank outward.
CAUTION: To ensure proper system cooling, the power supply unit blank must be
installed in the second power supply unit bay in a non-redundant configuration.
Remove the power supply unit blank only if you are installing a second power supply
unit.
Installing a Power Supply Unit blank
l
Follow the safety guidelines listed in
N
OTE
:
Install the power supply unit (PSU) blank only in the second PSU bay.
Follow the below steps to install the Power Supply Unit blank:
1. Align the PSU blank with the PSU slot and push it into the PSU slot until it clicks
into place.
After installing a Power Supply Unit follow the procedure listed in
.
Removing a Power Supply Unit
CAUTION: The system needs one power supply unit (PSU) for normal operation. On
power-redundant systems, remove and replace only one PSU at a time in a system
that is powered on.