How to setup AWC function
This section will show you how to setup and assign an Automatic Water Change function. First,
you will create the function, then you will assign the function to outlets on your GHL Powerbar.
In order to setup AWC control, you will need certain items. These items can be purchased at
your preferred GHL dealer:
Items needed for AWC control
PL-1095 PL-LF-Base 2 (Assembly rod)
Any combination of 2 sensors: PL-0077 Float sensor OR PL-0082 Optical sensor.
PL-0723 PL-LF-S12 (For optical sensor)
PL-0080 PL-LF-S8 (For float sensor)
NOTE
This section will show you how to get an AWC function running with a
dedicated AWC DRAIN pump and AWC FILL pump. In order for the AWC
feature to work, these pumps must be connected to your powerbar.
NOTE
AWC functions are activated through the TIMER functions. In the steps that
follow, you will select a TIMER to use for activating the AWC command.