Auto Top Off – When a single sensor detects a low water level,
the Powerbar socket with the function,
Fill Water
, will turn on.
When normal water level is reached, the socket will turn off.
a.
ATO Always active – Checking this box will automate the
ATO function. Not having the box checked will require you
to create a timer function for this ATO. It is this timer
function which will dictate when the ATO function will be
enabled.
Leakage detection – If a sensor is triggered, ProfiLux will
assume a leakage and trigger an alarm. By default, Powerbar
sockets with the function,
Fill Water
, stay ON with this function. If
a leakage is detected, the assigned sockets will turn OFF.
Return pump – If a single sensor detects that the water level is
too high, the Powerbar socket with the function,
Fill Water
, is
turned ON. When normal water level is reached, the assigned
socket will turn OFF.
Min/Max control
–
Two sensors are used to control a water
level. Sensor 1 (S1) works as the max-point and Sensor 2 (S2) is
the min-point. As soon as S2 detects a low water level, the
Powerbar socket with the function,
Fill Water
, is turned ON. When
normal water level is reached, the socket will turn OFF.
Water change – Two sensors are used to perform water
changes. When a water change event is activated, the socket with
the function,
Drain Water
, will turn ON and stay ON until the
water level reaches sensor 2, min-point. The Powerbar socket with
the function,
Fill Water
, will then turn ON and stop when the
water level reaches Sensor 1, max-point.
ATO & Water change – Works just like the water change
function, but also includes ATO function. With this mode, Sensor 1
serves a dual purpose, it becomes the ATO sensor and Max-point
sensor for AWC. When this sensor detects low water level, it will
turn on the Powerbar socket with the function,
Fill Water (ATO
only)
.
ATO 2 sensors – Works just like a normal ATO function, but
instead uses 2 sensors to register the same water level. The
Powerbar socket with the function,
Fill Water
, will only turn on
when BOTH sensors register a low water level. Useful for
providing additional safety.
ii.
Maximum On-time: This feature is used for setting the max on-time for
a specific sensor. If a sensor fails to deactivate the assigned function, the
corresponding Powerbar socket will shut OFF and an alarm will be