2.
Set this function to PROGRAMMABLE LOGIC and select the
Gate
number you used when
you created the PL function.
a.
For example, if you selected Gate 2 (G2) to create the PL function, select
PROGRAMMABLE LOGIC 1.
3.
Type-in a description and click OK.
4.
Click SAVE CHANGES.
Combining multiple PL functions (Using AND function)
Scenario: If you want to assign more than 2 functions to a Powerbar outlet, you can do so by
creating your PL functions, then using a new PL gate to assign those PL functions to the new PL
function. For example, if you want to have a skimmer react to 3 separate functions:
Turn ON from 8am – 8pm (Timer function)
Turn OFF during a Feed Pause (Filter function)
Turn OFF if sump water level gets too high (Fill water assigned for Leakage Detection)
You would use 2 Programmable Logic functions where the first PL function (Gate 1) would have
Input 1
assigned to TIMER function,
Input 2
would be assigned to FILTER function, and PL
function itself assigned as an AND function.
You would then select another PL function (Gate 2).
Input 1
would be assigned
PROGRAMMABLE LOGIC (X) with X being the gate number you used earlier. Input 2 would be
assigned to FILL WATER (X) with X being the Control circuit number you used when you
created the LEAKAGE DETECTION function. It would look like this: