TSA 160 NT
37
Mains connection
18.3 Two automated door leaves TSA 160 NT
à
Drive nominal power 2 x 300 W
9
T4AH
1
Mains fuse (on site) *)
2
Main switch (provided by customer) **)
3
passive leaf drive
4
Fuse terminal strip, fuse 5×20 mm, T4AH/250 V AC
5
Ferrite sleeve
6
Earthing base plate
7
Earthing drive hood
8
Intermediate cover kit
9
Active leaf drive
*) The customer must use an on-site automatic cut-out as the line-side disconnecting device, the dimensioning
of which is matched to the type, cross-section, type of routing and ambient conditions of the on-site feeder
(at least 6 A, maximum 16 A).
**) Necessary in accordance with EN 60335-1, section 22.2.