Commissioning and service
21.4.1 Configuring the active leaf control
à
For parameter setting with the service terminal ST220, the control to be configured can be selected via the
Service menu.
à
For parameter setting with the service push buttons S1 and S2, parameter setting can take place directly at the control
to be configured.
à
For parameter setting with the DPS, selection of the control to be configured (active or passive leaf) is not possible.
Parameter setting with the DPS is carried out as follows:
X
If connected, set the internal programme switch II (AUT) or MPS to AUT.
X
Switch off the mains power supply of the drive.
X
With 2-leaf drive, disconnect the RS485 connection active leaf/passive leaf control (connector RS485/ASF or
connector RS485).
X
Connect DPS to the active leaf control.
X
Switch on the supply voltage of the drive.
X
With TSA 160 NT F press the reset switch.
X
Open the Service menu by pressing the hidden service push button and the ENTER push button (exit only)
at the same time.
X
Carry out the required parameter settings.
X
Exit the Service menu by pressing the hidden Service push button and the push button x (night mode) at the same time.
X
Switch off the mains power supply of the drive.
X
Disconnect DPS from the control again.
X
With 2-leaf drive, re-establish the RS485 connection active leaf/passive leaf control (connector RS485/ASF or
connector RS485).
X
Switch on the mains voltage.
For TSA 160 NT F:
X
Press the reset switch.
X
Check the changed functions and if necessary adjust.
21.4.2 Configuring the passive leaf control
à
For parameter setting with the service terminal ST220, the control to be configured can be selected via the Service menu.
à
For parameter setting with the service push buttons S1 and S2, parameter setting can take place directly
at the control to be configured.
à
For parameter setting with the DPS, selection of the control to be configured (active or passive leaf) is not possible.
Parameter setting with the DPS is carried out as follows:
X
If connected, set the internal programme switch II (AUT) or MPS to AUT.
X
Switch off the mains power supply of the drive.
X
Disconnect the RS485 connection to the active leaf/passive leaf control (plug RS485/ASF or plug RS485).
X
Connect the DPS to the passive leaf control.
X
Switch on the supply voltage of the drive.
X
With TSA 160 NT F press the reset switch.
X
Open the Service menu by pressing the hidden service push button and the ENTER push button (exit only)
at the same time.
X
Carry out the required parameter settings.
X
Exit the Service menu by pressing the hidden Service push button and the push button x (night mode)
at the same time.
X
Switch off the mains power supply of the drive.
X
Disconnect DPS from the control again.
X
Set up RS485 connection active leaf/passive leaf control again (connector RS485/ASF or connector RS485).
X
Switch on the mains voltage.
For TSA 160 NT F:
X
Press the reset switch.
X
Check the changed functions and if necessary adjust.