TSA 160 NT
17
Safety sensor open and close
5.4.1 Monitoring closing and opening
X
Setting the contact type parameter:
à
DPS: Set
s1
to
0 2
(“normally closed contact”) and
s3
to
0 2
(“normally closed contact”) (factory setting).
à
ST220: Set the “Input signals”, “SI1 – terminal SIS”, “SI1 contact type” to “normally closed contact” and
“SI3 – terminal SIO”, “SI3 contact type” to “normally closed contact” (factory setting).
à
S1, S2: Set parameter 7 and 9 to 02 “NC”.
X
Setting the function parameter:
à
DPS: Set
f1
to the desired function and
f3
to
0 5
(“SIO stop“) or
0 6
(“SIO stop SF GF“).
à
ST220: Set the “Input signals”, “SI1 – terminal SIS”, “SI1 function” to the desired function and “SI3 – terminal
SIO”, “SI3 function” to “SIO stop” or “SIO stop SF GF”.
à
S1, S2: Set parameter 8 to the desired function.
Set parameter 10 to 05 “SIO Stop” or 06 “SIO stop SF GF”.
1
GND
13
SIO
10
TST
2
24V
SIO
1
GND
11
SIS
10
TST
2
24V
SIS
WH
BN
GY
GN
PK
YE
6
5
4
3
2
1
60mA
-
+
Test
6
5
4
3
2
1
60mA
-
+
Test
1
2
3
4
5
6
7
8
9
10
-
+
Test
WH
BN
GY
GN
PK
YE
4
5
1
1
2
3
1
GC 335 slaves
2
GC 335 master opposite hinge side
3
GC 335 adapter
4
Door transmission cable
5
GC 335 master hinge side