Service menu
Designation
Setting values
Explanation
P-KI activation
NO
Additional contact sensor KI
P-KA activation
NO
Additional contact sensor KA
Switch function
NO
With 2-leaf assemblies the push button can be
connected to the active leaf control or to the
passive leaf control.
When the push button is pressed once, the
drive opens the door. When the push button is
pressed again, the drive closes the door.
If the push button is connected to the passive
leaf control opening and closing when both door
leaves are activated if the internal programme
switch of the passive leaf control is set to AUT.
Switch function hold-
open time (OHZ)
NO
With 2-leaf assemblies the push button can be
connected to the active leaf control or to the
passive leaf control. When the push button is
pressed once, the drive opens the door and
closes after the hold-open time has expired.
When the push button is pressed again (within
the hold-open time) the drive closes the door
without waiting for the hold-open time to expire.
If the push button is connected to the active
leaf, the 1-leaf hold-open time is used for 1-leaf
use and the 2-leaf hold-open time for 2-leaf use.
Reset switch
NO
For restarting the drive.
Function as reset.
Double push button NO
Press 1 x: GF opens;
Press 2 x: SF also opens
Stop normally opened
contact
NO
For connection of a stop push button
Stop normally closed
contact
NC
PS-NA
NO
Night mode programme
PS-LS
NO
Exit only programme
Closed position SF
SF or door closer closed.
WC control
NO
with IO 420
1-leaf opening
NO
Only on the active leaf (2-leaf drive)
OFF normally closed
contact
NC
Switchover to OFF
PE2
Current state
PE2
Z-> inactive
K -> not used
F -> not used
Display
PE2 function
Not used
Input PE2 without function
OFF
NO
Switchover to OFF (normally opened contact)
Switchover summer
NO
For the connection of a push button for the
summer function.
Only for switching from 1-leaf to 2-leaf opening,
not for actually opening the door
Switchover winter
NO
For the connection of a push button for the winter
function. Only for switching from 2-leaf to 2-leaf
opening, not for actually opening the door.
Sabotage
NC
Permanently switched. If the contact is inter-
rupted KB is not evaluated in the night
mode of operation. All other functions remain the same.