Configurable inputs
11.11 WC control
Only use the fail-safe electric strikes.
à
In the event of a power failure the door is freely passable.
à
The “OCCUPIED” changeover switch switches between the AUTOMATIC and NIGHT modes of operation.
à
When the switch is set to “OCCUPIED”, the NIGHT mode of operation is set and activation via KI or KA is not
possible. The “OCCUPIED” signal lamps are switched on.
à
The door can only be opened from the outside using the mechanical contact KB.
à
Operation without display programme switch or keypad programme switch.
Put the internal programme switch for the drive out of operation:
X
Remove the tab connector of the red wire (24V) from the internal programme switch and insulate it.
Parameter settings:
X
Set
e1
or
e2
to
17
(PS-Night).
Accessories:
à
AS500 switch unit with illuminated display for disabled WC, mat. no. 47953
à
SLE, signal lamp, flush-mounted, AS500, AW, pre-mounted, mat. no. 115942
24V
AUT
DO
2
8
9
DCU5
PS
DCU5
51 PE1
1
GND
DCU5
PE1
52 PE2
DCU5
PE2
or
1
2
1
AS500 switch unit “OCCUPIED” INSIDE
2
SLE signal lamp “OCCUPIED” OUTSIDE