TSA 160 NT
11
Safety sensor open and close
5.1.2 Monitoring opening
X
Setting the contact type parameter:
à
DPS: Set
s3
to
0 2
(“normally closed contact”)
(factory setting).
à
ST220: Set the “Input signals”, “SI3 – terminal SIO”,
“SI3 contact type” to “normally closed
contact” (factory setting)
à
S1, S2: Set parameter 9 to 02 “normally closed
contact”.
X
Setting the function parameter:
à
DPS: Set
f3
to
0 5
(SIO stop) or
to
0 6
SIO stop SF GF).
à
ST220: Set the “Input signals”, “SI3 – terminal SIO”,
“SI3 function” to “SIO stop” or “SIO stop SF GF”.
à
S1, S1: Set parameter 10 to 05 “SIO Stop” or 06
“SIO stop SF GF”.
1
Opposite hinge side
2
Hinge side
3
Door transmission cable
4
GC 338 interface module
1
13
10
2
SIO
SIO
GND
24V
TST
S
E
GY
2
1
4
3
5
BN
BK
BU
WH
SIGNAL
24V
SIO
GND
SIS
100mA
2
1
3
4
5.1.3 Monitoring closing
X
Setting the contact type parameter:
à
DPS: Set
s1
to
0 2
(“normally closed contact”)
(factory setting).
à
ST220: Set the “Input signals”, “SI1 – terminal SIS”,
“SI1 contact type” to “normally closed
contact” (factory setting).
à
S1, S1: Set parameter 7 to 02 “normally closed
contact”.
X
Setting the function parameter:
à
DPS: Set
f1
to the desired function.
à
ST220: Set the “Input signals”, “SI1 – terminal SIS”,
“SI1 function” to the desired function.
à
S1, S1: Set parameter 8 to the desired function.
1
Hinge side
2
Opposite hinge side
3
Door transmission cable
4
GC 338 interface module
1
11
10
2
SIS
SIS
GND
24V
TST
S
E
GY
2
1
4
3
5
BN
BK
BU
WH
SIGNAL
24V
SIO
GND
SIS
100mA
2
1
3
4
Summary of Contents for TSA 160 NT F
Page 61: ...TSA 160 NT 61 Fault messages ...
Page 62: ...TSA 160 NT 62 Fault messages ...
Page 63: ...TSA 160 NT 63 Fault messages ...