TSA 160 NT
33
2-leaf drives
14 2-leaf drives
14.1 TSA 160 NT IS-TS: Active leaf automated, passive leaf with TS 160
à
Programme switch, mat. no. 72526
X
Setting the parameters:
à
DPS: Set
ef
to
0 0
for 1-leaf drive
Os
(hold-open time KB) in such a way that the passive leaf only closes when the active leaf is in
closing position.
à
ST220: Set “Door parameters”, “Number of leaves” to “1-leaf drive”.
Set “Movement parameters”, “Hold-open times”, “Mechanical contact” in such a way that the active
leaf does not close until the passive leaf is in the closing position.
à
S1, S2: Set parameter 1 to 00 for 1-leaf drive, parameter 3 (hold-open time KB) in such a way that the active
leaf does not close until the passive leaf is in the closing position.
à
Diode 1N4007, mat. no. 115293
1
Terminal strip intermediate cover
2
Terminal strip SF
3
Free swing diode
4
Solenoid valve 24 V/160 mA
1N4007
GN
GN
RD
BK
14.2 Two automated door leaves
X
Setting the parameters:
à
DPS: Set
ef
to
01
for active leaf drive or to
0 2
for passive leaf drive.
à
ST220: Set “Door parameters”, “Number of leaves” to “2-leaf active” or “2-leaf passive”.
à
S1, S2: Parameter 1 to 01 for active leaf drive or to 02 for passive leaf drive.
14.2.1 Connection via system cable RS485
à
RS485 connection cable, mat. no. 120048
3
2
1
RS485/ASF GF
RS485_B
RS485_A
GND
3
2
1
RS485_B
RS485_A
GND
RS485/ASF SF
GN
BN
WH
14.2.2 Connection via standard cable RS485
Do not connect terminal 2.
1
GND
2
24V
42
RS485-A
41
RS485-B
43
SCR
RS485 GF
GND
1
2
24V
42 RS485-A
41 RS485-B
43 SCR
RS485 SF