TSA 160 NT
36
Mains connection
18 Mains connection
18.1 TSA 160 NT 1-leaf
à
Drive nominal power 300 W
1
Mains fuse (on site) *)
2
Main switch (provided by customer) **)
3
Door drive unit
4
Fuse terminal strip,
fuse 5×20 mm, T4AH/250 V AC
5
Earthing base plate
6
Earthing drive hood
7
Ferrite sleeve
7
T4AH
*) The customer must use an on-site automatic cut-out as the line-side disconnecting device, the dimensioning
of which is matched to the type, cross-section, type of routing and ambient conditions of the on-site feeder
(at least 6 A, maximum 16 A).
**) Necessary in accordance with EN 60335-1, section 22.2.
18.2 TSA 160 NT IS-TS: Active leaf automated, passive leaf with TS 160
à
Drive nominal power 300 W
à
Cable harness intermediate cover kit , L = 2120, mat. no. 130132
à
230 V fuse terminal strip, mat. no. 120522
10
T4AH
1
Mains fuse, provided by customer *)
2
Main switch, on site**)
3
Door closer, passive leaf
4
Fuse terminal strip, fuse 5×20 mm, T4AH/250 V AC
5
Ferrite sleeve
6
Mains plug door closer passive leaf
7
Base plate
8
Drive hood
9
Intermediate hood kit
10
Active leaf drive
*) The customer must use an on-site automatic cut-out as the line-side disconnecting device, the dimensioning
of which is matched to the type, cross-section, type of routing and ambient conditions of the on-site feeder
(at least 6 A, maximum 16 A).
**) Necessary in accordance with EN 60335-1, section 22.2.