Safety sensor open and close
5.3 Safety sensor GC 334
à
GC 334 module, mat. no. 126410
X
Follow the installation instructions.
X
Set testing:
à
DPS: Set
Te
to
0 2
(testing with GND).
à
ST220: Set “Output signals”, “Testing SI” to “Testing with GND”.
à
S1, S2: Set parameter 11 to 02 “Testing with GND”.
à
Max. 6 modules in series
5.3.1 Monitoring closing and opening
X
Setting the contact type parameter:
à
DPS:
Set
s1
to
0 2
(“normally closed contact”) and
s3
to
0 2
(“normally closed contact”)
(factory setting).
à
ST220: Set the “Input signals”, “SI1 – terminal
SIS”, “SI1 contact type” to “normally
closed contact” and “SI3 – terminal
SIO”, “SI3 contact type” to “normally
closed contact” (factory setting).
à
S1, S2: Set parameter 7 and 9 to 02 “NC”.
X
Setting the function parameter:
à
DPS:
Set
f1
to the desired function and
f3
to
0 5
(“SIO stop“) or
0 6
(“SIO stop SF GF“).
à
ST220: Set the “Input signals”, “SI1 – terminal SIS”,
“SI1 function” to the desired function and
“SI3 – terminal SIO”, “SI3 function” to “SIO
stop” or “SIO stop GF SF”.
à
S1, S2: Set parameter 8 to the desired function.
Set parameter 10 to 05 “SIO Stop”
or 06 (SIO stop SF GF).
à
Configuration of the GC 334 modules on the
à
Hinge side:
DIP1 = ON
à
Opposite hinge side: DIP1 = OFF
SIS
1
GND
11 SIS
10 TST
2
24V
1
GND
13 SIO
10 TST
2
24V
SIO
VT
PK
WH
YE
BN
-
+
GN
BU
-
+
RD
60mA
1
2
3
4
5
1
1
GC 334 module
2
Opposite hinge side
3
Hinge side
4
Door transmission cable
5
GC 334 opposite hinge side
Summary of Contents for TSA 160 NT F