BIT SWITCHES
SM 39
B603
Fax Op
tion
B60
3
System
Switch
1E
SP
No.
1-101-031
No FUNCTION
COMMENTS
2
RTI/CSI display priority
0: RTI 1: CSI
This bit determines which identifier, RTI or CSI, is
displayed on the LCD while the machine is
communicating in G3 non-standard mode.
3
File No. printing
0
: Enabled
1
: Disabled
1:
File numbers are not printed on any reports.
4
Action when authorized
reception is enabled but
authorized RTIs/CSIs are
not
yet
programmed
0
: All fax reception is disabled
1
: Faxes can be received if the
sender has an RTI or CSI
If authorized reception is enabled but the user has
stored no acceptable sender RTIs or CSIs, the
machine will not be able to receive any fax
messages.
If the customer wishes to receive messages from
any sender that includes an RTI or CSI, and to block
messages from senders that do not include an RTI
or CSI, change this bit to “1”, then enable
Authorized Reception.
Otherwise, keep this bit at “0 (default setting)”.
5-6
Not used
Do not change the setting.
7
RAM initialization after the
optional Function Upgrade unit
is installed or removed
0:
Enabled
1:
Disabled
When the machine detects that a Function Upgrade
unit has been installed or removed, the machine
shows the following message on the display for the
customer.
“Adding/Removing FAX Feature Expander causes
data loss. Turn Main Power Switch off and
remove/replace it to avoid loss. To continue, press
Yes.”
If Yes is pressed, the machine initializes the RAM to
the “with” or “without card” configuration. However,
changing this bit to “1” disables this initialization,
even if Yes is pressed.
Change this bit to 1 after installing the Function
Upgrade unit.
0:
When the above message is displayed, the
machine initializes the RAM if Yes is pressed. The
amount of data lost depends on whether the board
is in or out. To avoid losing data, the user must
switch off immediately and put the Function
Upgrade unit back in.
1:
When the above message is displayed, the
machine does not initialize the RAM even if Yes is
pressed. However, the fax unit cannot be used until
the user switches off, puts the Function Upgrade
unit back in, then switches back on. No data is lost.
Summary of Contents for B147
Page 1: ...B147 B149 B190 SERVICE MANUAL 001892MIUMIU RICOH GROUP COMPANIES...
Page 2: ......
Page 3: ...B147 B149 B190 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 4: ......
Page 5: ...B147 B149 B190 SERVICE MANUAL 001892MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 26: ......
Page 30: ......
Page 32: ......
Page 33: ...INSTALLATION...
Page 34: ......
Page 105: ...PREVENTIVE MAINTENANCE...
Page 106: ......
Page 112: ......
Page 113: ...REPLACEMENT AND ADJUSTMENT...
Page 114: ......
Page 201: ...TROUBLESHOOTING...
Page 202: ......
Page 287: ...SERVICE TABLES...
Page 288: ......
Page 456: ......
Page 457: ...DETAILED DESCRIPTIONS...
Page 458: ......
Page 589: ...SPECIFICATIONS...
Page 590: ......
Page 607: ...AUTO REVERSE DOCUMENT FEEDER B597...
Page 608: ......
Page 610: ......
Page 634: ......
Page 635: ...ONE TRAY PAPER FEED UNIT B601...
Page 636: ......
Page 638: ......
Page 647: ...TWO TRAY PAPER FEED UNIT B598...
Page 648: ......
Page 650: ......
Page 659: ...LARGE CAPACITY TRAY B600...
Page 660: ......
Page 662: ......
Page 680: ......
Page 681: ...TWO TRAY FINISHER B599...
Page 682: ......
Page 714: ......
Page 715: ...BOOKLET FINISHER B602...
Page 716: ......
Page 720: ......
Page 729: ...STAPLER UNIT SM 9 B602 Booklet Fin isher B602 13 Timing belt A 14 Gear B x 1 B602R920 WMF A B...
Page 791: ...FAX OPTION TYPE 2238 B603...
Page 792: ......
Page 902: ......
Page 903: ...INTERNET FAX IFAX...
Page 904: ......
Page 950: ......
Page 951: ...DataOverwriteSecurity Unit Type A B694 01 Type B B692 01...
Page 952: ......
Page 954: ......
Page 958: ......
Page 980: ...TECHNICAL SERVICE BULLETINS...
Page 1066: ...FIRMWARE HISTORY...