680576
Number of rings until a call is
detected
1
Function 06-2 (parameter
06).
The setting must not be
zero.
680577
Minimum required length of the first
ring
20 ms
See Note 4.
Function 06-2 (parameter
07).
680578
Minimum required length of the
second and subsequent rings
20 ms
Function 06-2 (parameter
06-2).
680579
Ringing signal detection reset time
(LOW)
Function 06-2 (parameter
09).
68057A
Ringing signal detection reset time
(HIGH)
20 ms
Function 06-2 (parameter
10).
68057B
to
680580
Not used
Do not change the
settings.
680581
Interval between dialing the last digit
and switching the Oh relay over to
the external telephone when dialing
from the operation panel in handset
mode.
20 ms
Factory setting: 500 ms
680582
Bits 0 and 1 - Handset off-hook detection time
Bit 1 0 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 2 and 3 - Handset on-hook detection time
Bit 3 2 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 4 to 7 - Not used
680583
to
6805A0
Not used
Do not change the
settings.
6805A1
Acceptable CED detection frequency
upper limit (high byte)
6805A2
Acceptable CED detection frequency
upper limit (low byte)
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
6805A3
Acceptable CED detection frequency
lower limit (high byte)
6805A4
Acceptable CED detection frequency
lower limit (low byte)
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
6805A5
CED detection time
20 ms
±
20 ms
Factory setting: 200 ms
6805A6
Acceptable CNG detection frequency
upper limit (high byte)
6805A7
Acceptable CNG detection frequency
upper limit (low byte)
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
Summary of Contents for B147
Page 1: ...B147 B149 B190 SERVICE MANUAL 001892MIUMIU RICOH GROUP COMPANIES...
Page 2: ......
Page 3: ...B147 B149 B190 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 4: ......
Page 5: ...B147 B149 B190 SERVICE MANUAL 001892MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 26: ......
Page 30: ......
Page 32: ......
Page 33: ...INSTALLATION...
Page 34: ......
Page 105: ...PREVENTIVE MAINTENANCE...
Page 106: ......
Page 112: ......
Page 113: ...REPLACEMENT AND ADJUSTMENT...
Page 114: ......
Page 201: ...TROUBLESHOOTING...
Page 202: ......
Page 287: ...SERVICE TABLES...
Page 288: ......
Page 456: ......
Page 457: ...DETAILED DESCRIPTIONS...
Page 458: ......
Page 589: ...SPECIFICATIONS...
Page 590: ......
Page 607: ...AUTO REVERSE DOCUMENT FEEDER B597...
Page 608: ......
Page 610: ......
Page 634: ......
Page 635: ...ONE TRAY PAPER FEED UNIT B601...
Page 636: ......
Page 638: ......
Page 647: ...TWO TRAY PAPER FEED UNIT B598...
Page 648: ......
Page 650: ......
Page 659: ...LARGE CAPACITY TRAY B600...
Page 660: ......
Page 662: ......
Page 680: ......
Page 681: ...TWO TRAY FINISHER B599...
Page 682: ......
Page 714: ......
Page 715: ...BOOKLET FINISHER B602...
Page 716: ......
Page 720: ......
Page 729: ...STAPLER UNIT SM 9 B602 Booklet Fin isher B602 13 Timing belt A 14 Gear B x 1 B602R920 WMF A B...
Page 791: ...FAX OPTION TYPE 2238 B603...
Page 792: ......
Page 902: ......
Page 903: ...INTERNET FAX IFAX...
Page 904: ......
Page 950: ......
Page 951: ...DataOverwriteSecurity Unit Type A B694 01 Type B B692 01...
Page 952: ......
Page 954: ......
Page 958: ......
Page 980: ...TECHNICAL SERVICE BULLETINS...
Page 1066: ...FIRMWARE HISTORY...