COPY
SERVICE
MODE
SM 5-31
B147/B149/B190
Service
Tables
3-905
[M/A Target]
Adjusts the target amount of each toner on paper sheets.
These values are optimized before shipment. Do not change the values. Changing
these values does not affect toner density on paper sheets.
3-905-1 Intrvl
[K]
*BCU
3-905-2 Intrvl
[Y]
*BCU
3-905-3 Intrvl
[M]
*BCU
3-905-4 Intrvl
[C]
*BCU
[ 0 to 1.50 / 0.30 / 0.01 mg/cm
2
/step]
DFU
Displays the amount of each toner on the paper.
A problem may have occurred in the copier engine if the value is high or low (i.e., if
the difference between SP3-905-1/2/3/4 and SP3-5/6/7/8 is larger than
±
0.03
mg/cm
2
).
Possible problems: Defective TD sensor, defective ID sensor, toner near-end (if the
value is lower than the target), defective toner supply mechanism
3-905-5 Intrvl
[K]
*BCU
3-905-6 Intrvl
[Y]
*BCU
3-905-7 Intrvl
[M]
*BCU
3-905-8 Intrvl
[C]
*BCU
[ 0 to 1.500 / - / 0.001 mg/cm
2
/step]
3-906
[PC Self Check]
Process Control Self-checks
Job End
*BCU [ 0 to 999 / 200 / 1 print/step ]
3-906-1
Specifies the execution timing of the job end process control self-check.
The job end process control self-check is automatically done after a job is completed
when 200 prints have been made since the last self-check.
The counter for the job end process control self-check resets when one of the
following process control self-checks is done.
•
Initial
•
Interval: Interrupt
•
Non-use Time
•
During Toner End
When K prints are made, the number of prints is calculated with the K coefficient in
SP3-906-5.
Interrupt
*BCU [ 0 to 999 / 0 / 1 print/step ]
3-906-2
Specifies the execution timing of the interrupt process control self-check.
The interrupt process control self-check is automatically done if the number of prints
in the job exceeds the number set in this SP mode. When the print job is completed,
the counter is reset, even if the interrupt self check did not occur.
When K prints are made, the number of prints is calculated with the K coefficient in
SP3-906-5.
Non-use Time 1
*BCU [ 0 to 999 / 0 / 1 print/step ]
0: Disable
3-906-3
Specifies the executing timing of the non-use time process control self-check.
The non-use time process control self-check is automatically done after the number of
prints set with this SP mode have been made and no prints have been made for the
time set with SP mode 3-906-4 since the last print job.
If the conditions are met, the self-check will be done after the print job is completed.
The counter is reset when the initial process control self-checks is done or when a
print is made.
Non-use Time 2
*BCU [ 0 to 2550 / 480 / 10 minutes/step ]
0: Disable
3-906-4
Specifies the executing timing of the non-use time process control self-check.
Summary of Contents for B147
Page 1: ...B147 B149 B190 SERVICE MANUAL 001892MIUMIU RICOH GROUP COMPANIES...
Page 2: ......
Page 3: ...B147 B149 B190 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 4: ......
Page 5: ...B147 B149 B190 SERVICE MANUAL 001892MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 26: ......
Page 30: ......
Page 32: ......
Page 33: ...INSTALLATION...
Page 34: ......
Page 105: ...PREVENTIVE MAINTENANCE...
Page 106: ......
Page 112: ......
Page 113: ...REPLACEMENT AND ADJUSTMENT...
Page 114: ......
Page 201: ...TROUBLESHOOTING...
Page 202: ......
Page 287: ...SERVICE TABLES...
Page 288: ......
Page 456: ......
Page 457: ...DETAILED DESCRIPTIONS...
Page 458: ......
Page 589: ...SPECIFICATIONS...
Page 590: ......
Page 607: ...AUTO REVERSE DOCUMENT FEEDER B597...
Page 608: ......
Page 610: ......
Page 634: ......
Page 635: ...ONE TRAY PAPER FEED UNIT B601...
Page 636: ......
Page 638: ......
Page 647: ...TWO TRAY PAPER FEED UNIT B598...
Page 648: ......
Page 650: ......
Page 659: ...LARGE CAPACITY TRAY B600...
Page 660: ......
Page 662: ......
Page 680: ......
Page 681: ...TWO TRAY FINISHER B599...
Page 682: ......
Page 714: ......
Page 715: ...BOOKLET FINISHER B602...
Page 716: ......
Page 720: ......
Page 729: ...STAPLER UNIT SM 9 B602 Booklet Fin isher B602 13 Timing belt A 14 Gear B x 1 B602R920 WMF A B...
Page 791: ...FAX OPTION TYPE 2238 B603...
Page 792: ......
Page 902: ......
Page 903: ...INTERNET FAX IFAX...
Page 904: ......
Page 950: ......
Page 951: ...DataOverwriteSecurity Unit Type A B694 01 Type B B692 01...
Page 952: ......
Page 954: ......
Page 958: ......
Page 980: ...TECHNICAL SERVICE BULLETINS...
Page 1066: ...FIRMWARE HISTORY...