DEDICATED TRANSMISSION PARAMETERS
B603 84 SM
3.4.2 PARAMETERS
The initial settings of the following parameters are all FF(H) - all the parameters are
disabled.
Switch 00
FUNCTION AND COMMENTS
ITU-T T1 time (for PSTN G3 mode)
If the connection time to a particular terminal is longer than the NCU parameter setting,
adjust this byte. The T1 time is the value stored in this byte (in hex code), multiplied by 1
second.
Range:
0 to 120 s (00h to 78h)
FFh - The local NCU parameter factory setting is used.
Do not program a value between 79h and FEh.
Switch 01
No FUNCTION
COMMENTS
0
to
4
Tx level
Bit 4 3 2 1 0 Setting
0 0 0 0 0 0
0 0 0 0 1 -1
0 0 0 1 0 -2
0 0 0 1 1 -3
0 0 1 0 0 -4
:
:
0 1 1 1 1 -15
1 1 1 1 1 Disabled
If communication with a particular remote terminal
often contains errors, the signal level may be
inappropriate. Adjust the Tx level for
communications with that terminal until the results
are better.
If the setting is “Disabled”, the NCU parameter 01
setting is used.
Note:
Do not use settings other than listed on the
left.
5
to
7
Cable equalizer
Bit 7 6 5 Setting
0 0 0 None
0 0 1 Low
0 1 0 Medium
0 1 1 High
1 1 1 Disabled
Use a higher setting if there is signal loss at higher
frequencies because of the length of wire between
the modem and the telephone exchange when
calling the number stored in this Quick/Speed Dial.
Also, try using the cable equalizer if one or more of
the following symptoms occurs.
•
Communication error with error codes such as
0-20, 0-23, etc.
•
Modem rate fallback occurs frequently.
Note:
Do not use settings other than listed on the
left.
If the setting is “Disabled”, the bit switch setting is
used.
Summary of Contents for B147
Page 1: ...B147 B149 B190 SERVICE MANUAL 001892MIUMIU RICOH GROUP COMPANIES...
Page 2: ......
Page 3: ...B147 B149 B190 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 4: ......
Page 5: ...B147 B149 B190 SERVICE MANUAL 001892MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 26: ......
Page 30: ......
Page 32: ......
Page 33: ...INSTALLATION...
Page 34: ......
Page 105: ...PREVENTIVE MAINTENANCE...
Page 106: ......
Page 112: ......
Page 113: ...REPLACEMENT AND ADJUSTMENT...
Page 114: ......
Page 201: ...TROUBLESHOOTING...
Page 202: ......
Page 287: ...SERVICE TABLES...
Page 288: ......
Page 456: ......
Page 457: ...DETAILED DESCRIPTIONS...
Page 458: ......
Page 589: ...SPECIFICATIONS...
Page 590: ......
Page 607: ...AUTO REVERSE DOCUMENT FEEDER B597...
Page 608: ......
Page 610: ......
Page 634: ......
Page 635: ...ONE TRAY PAPER FEED UNIT B601...
Page 636: ......
Page 638: ......
Page 647: ...TWO TRAY PAPER FEED UNIT B598...
Page 648: ......
Page 650: ......
Page 659: ...LARGE CAPACITY TRAY B600...
Page 660: ......
Page 662: ......
Page 680: ......
Page 681: ...TWO TRAY FINISHER B599...
Page 682: ......
Page 714: ......
Page 715: ...BOOKLET FINISHER B602...
Page 716: ......
Page 720: ......
Page 729: ...STAPLER UNIT SM 9 B602 Booklet Fin isher B602 13 Timing belt A 14 Gear B x 1 B602R920 WMF A B...
Page 791: ...FAX OPTION TYPE 2238 B603...
Page 792: ......
Page 902: ......
Page 903: ...INTERNET FAX IFAX...
Page 904: ......
Page 950: ......
Page 951: ...DataOverwriteSecurity Unit Type A B694 01 Type B B692 01...
Page 952: ......
Page 954: ......
Page 958: ......
Page 980: ...TECHNICAL SERVICE BULLETINS...
Page 1066: ...FIRMWARE HISTORY...