GE-NUTRI USER’S GUIDE
GE-NUTRI
Section C-43
MAIN MENU
SETTINGS PROGRAM {1-4}
TIMERS PROGRAM {1-4}
PROXIMITY SWITCH FILTERS
1.
These parameters allow you to adjust the length of the start filter of the
proximity switch for each feed auger. During this period, the feed auger
assigned to the proximity switch won't stop even if the proximity switch is
active for its filter end time. For the feeding phase to end, the start filters
need to be done. In multi-feed mode, these time limits are reset for each feed
auger of the cycle. This setting can be adjusted in increments of 1 second
from 0 to 999 seconds.
2.
These parameters allow you to adjust the proximity switch activation time to
determine if the manger is full. These parameters are adjustable in
increments of 1 second from 0 to 999 seconds.
P . S w i t c h F i l t e r s
T i m e ( s e c )
S t a r t E n d
P . S w i t c h 1 : 1 5 1 5
P . S w i t c h 2 : 1 5 1 5
P . S w i t c h 3 : 1 5 1 5
P . S w i t c h 4 : 1 5 1 5
[1]