MAIN MENU
SETTINGS PROGRAM {1-4}
TIMERS PROGRAM {1-4}
ACTUATORS TIMERS
This screen can only be access in feeder auger drop and chain feeder drop.
1.
This setting allows you to adjust the opening time of the drop. If an actuator
does not have a position under 5% at the end of the delay, the alarm is
activated and the cycle is cancelled. If no potentiometer is used, the opening
time is equal to sum of the parameter plus the total run time of the actuator.
This setting varies in increments of 1 second from 0 to 300 seconds.
2.
This setting allows you to adjust the waiting time of the actuator. This setting
varies in increments of 1 second from 0 to 300 seconds.
3.
This parameter allows you to adjust the closing time of the drop. If an
actuator does not have a position above 95% at the end of the delay, the
alarm is activated and the cycle is cancelled. If no potentiometer is used, the
closing time is equal to sum of the parameter plus the total run time of the
actuator. This setting varies in increments of 1 second from 0 to 300
seconds.
A c t u a t o r T i m e r s
S t a r t i n g : 6 0 S e c
D i s t r i b . : 6 0 S e c
S t o p p i n g : 6 0 S e c
[1]
[3]
[2]