Maintenance - Checking - Cleaning
GEDA
®
MINI 60 S / MAXI 120 S / MAXI 150 S
Assembly and Operating Manual
66 / 90
BL068 GB Edition 03/2015
8.2
Maintenance schedule
The inspections to be carried out on a daily basis before the start of op-
eration are not included in the maintenance schedule. These are de-
scribed in the operating manual as these checks are usually carried out
by the operating personnel.
The maintenance intervals given relate to one-shift operation
(40 hours / week). The intervals are to be modified according to any de-
viating operating times. The following inspections always include a
check for proper function, wear, completeness and that there is no ma-
nipulation present.
Abbreviations used in the maintenance schedule
W = Week / M = Month / Y = Year
= Visual check / ■ = Check
W
1M
3M
1J
Electrical components
Check the control lines and mains supply
cable for signs of damage.
Abrasion protection for cables
Function check of the manual control
■
Switching mechanism and limit switch
■
Check / tighten the firmness of the con-
tacts
■
Check the overload setting
■
Protective earth measurement in accord-
ance with EN 60204, Part 1
■
1
Insulation measurement in accordance
with EN 60204, Part 1
■
1
Switch compartment (below the protective cover
Soiling, moisture, scorched areas
Mechanical components
Wire rope
damage / wear
■
Attachment devices
(secure seating/tighten)
■
Rope pulleys
■
All covers available
Motor brake
■
Grease escaping / anomalies gearbox
Information signs
(present / legible)
Fall protection
Attachment / aperture width
■
■
1
=
Maximum test intervals which could be significantly reduced depending on the
location of use and national regulations.
WARNING
Supplement the maintenance plan with details regarding maintenance /
servicing / operating materials / replacement / repair of component
parts contained in the instructions provided by the suppliers.