2.9
Danger zones
Fig.8:
Danger zone at the valve
Please observe the following notes:
•
In the event of malfunctions, shut down the valve (disconnect from the power
and air supply) and secure it against being used.
•
Never reach into the lantern (9) or the valve housing (401) when the valve is
switching. Fingers can be crushed or cut off.
•
Do not reach into the feedback signal (E) when the valve is switching. Limbs
can be crushed or cut off.
•
On a spring-closing valve there is danger of injury when the clamp
connections (43, 44.46) are opened, as the released spring pretension will
suddenly lift the actuator. Therefore, release the spring tension before
detaching the clamp connections (43, 44, 46) by supplying the actuator (A)
with compressed air.
•
Before starting any maintenance, servicing or repair work, disconnect the
valve from the power supply and secure it against inadvertently being
switched back on again.
•
Only allow a qualified electrician to carry out any work on the electrical power
supply.
•
Check the electrical equipment of the valve at regular intervals. Immediately
remedy loose connections and molten cables.
•
If work on live parts cannot be avoided, call in a second person, who can
operate the main switch in case of an emergency.
Safety
Danger zones
430BAL013307EN_8
04.08.2022
17
Summary of Contents for D-tec D
Page 66: ...Fig 39 Maintenance Assembling the valve 430BAL013307EN_8 66 04 08 2022...
Page 69: ...Fig 41 Maintenance Assembling the valve 430BAL013307EN_8 04 08 2022 69...
Page 85: ...Fig 55 Housing Parts list D tec double chamber valve type D DV 430BAL013307EN_8 04 08 2022 85...
Page 91: ...Fig 58 hard seal Parts list D tec valve insert D DV SV NC NO 430BAL013307EN_8 04 08 2022 91...
Page 99: ...Fig 61 Dimension sheet double chamber valve type D DV 430BAL013307EN_8 04 08 2022 99...
Page 105: ...Appendix 430BAL013307EN_8 04 08 2022 105...
Page 106: ......