6.6.2.2 Hose connection diagram - double-chamber valve D/DV without control top
Fig.13
A
Actuator
L
Lift actuator
P
Valve - main stroke
Y2
Lift - valve disk
Y3
Lift - double seat disk
61
Stroke side valve
I = Proximity switch serves to detect the valve end position (main stroke actuated)
II = Proximity switch serves to detect the valve rest position (main stroke not actuated)
III = Proximity switch serves to detect the double disk rest position (double disk not lifted)
Hint!
For an optimal fit at the air connection, it is necessary to cut the
pneumatic hoses at a right angle with the hose cutter.
Assembly and installation
Pneumatic connections
430BAL013307EN_8
04.08.2022
33
Summary of Contents for D-tec D
Page 66: ...Fig 39 Maintenance Assembling the valve 430BAL013307EN_8 66 04 08 2022...
Page 69: ...Fig 41 Maintenance Assembling the valve 430BAL013307EN_8 04 08 2022 69...
Page 85: ...Fig 55 Housing Parts list D tec double chamber valve type D DV 430BAL013307EN_8 04 08 2022 85...
Page 91: ...Fig 58 hard seal Parts list D tec valve insert D DV SV NC NO 430BAL013307EN_8 04 08 2022 91...
Page 99: ...Fig 61 Dimension sheet double chamber valve type D DV 430BAL013307EN_8 04 08 2022 99...
Page 105: ...Appendix 430BAL013307EN_8 04 08 2022 105...
Page 106: ......