Fig.47
4.
Use the insertion tool to press in the V-ring – evenly press in at several
opposite points along the circumference.
Fig.48
5.
Insert the V-ring evenly.
6.
Replace all the other seals identified in the spare parts lists.
®
Done
Hint!
Used seals must not be used again, since the proper function of the
seal can then no longer be ensured.
10.7.4 Changing the stem diaphragm
See Section 10.5.2, Page 50 for details on changing the stem diaphragm.
See Section 10.6.1, Page 59 for details on assembly of the stem diaphragm.
10.7.5 Exchanging the O-ring (TEFASEP gold)
Tools required:
•
O-ring cutter
•
Heat-resistant protective gloves
•
Oven (no microwave)
Caution!
Health hazard due to toxic fumes!
The O-ring cutter cuts the seal with a hot metal tip. At temperatures of more
than 300 °C, toxic fumes can be released.
► Avoid directly inhaling the fumes.
Maintenance
Maintenance
430BAL013307EN_8
78
04.08.2022
Summary of Contents for D-tec D
Page 66: ...Fig 39 Maintenance Assembling the valve 430BAL013307EN_8 66 04 08 2022...
Page 69: ...Fig 41 Maintenance Assembling the valve 430BAL013307EN_8 04 08 2022 69...
Page 85: ...Fig 55 Housing Parts list D tec double chamber valve type D DV 430BAL013307EN_8 04 08 2022 85...
Page 91: ...Fig 58 hard seal Parts list D tec valve insert D DV SV NC NO 430BAL013307EN_8 04 08 2022 91...
Page 99: ...Fig 61 Dimension sheet double chamber valve type D DV 430BAL013307EN_8 04 08 2022 99...
Page 105: ...Appendix 430BAL013307EN_8 04 08 2022 105...
Page 106: ......