1.
Pressurise the actuator (140) at the connection (61) with compressed air,
max. 8 bar.
®
The valve disk (15) is raised.
2.
Loosen the valve disk (15) with a open-ended wrench on the spanner flats
(15.1) and unscrew it from the piston rod (140.1).
3.
Interrupt the compressed air supply to the connection (61).
®
The valve disk (15) is lowered.
4.
Firmly hold the actuator (140) with a strap wrench and unscrew the lantern (9)
from the actuator (140) with a hook wrench (Z).
®
All seals are freely accessible.
®