10.5.1.2 Disconnecting the valve from the housing
Fig.21:
Disconnecting the valve from the housing
Caution!
Risk of injury due to moving valve parts.
► Do not touch the lantern (9).
Warning!
Spring tension in the valve
Danger of injury when opening the clamp connections on the actuator or on
the housing as the released spring pretension will suddenly lift the actuator.
► Therefore, release the spring tension before detaching the clamp
connections by pressurising the actuator with compressed air at max. 8 bar.
Tools required:
•
Open-ended wrench
Carry out the following steps:
1.
Turn the connection (0) with the angled screw-in connection and reduction
nipple in the piston stem.
2.
Vent actuator at connection (0) with compressed air, max. 8 bar.
®
The valve insert is raised.
Maintenance
Disassembling the valve
430BAL013307EN_8
48
04.08.2022