Hydran 201C
i
-C Communications Controller
Part 17997
Rev. 6, March 2011
A-5
Note: General Electric Canada has made every reasonable attempt to ensure the comple-
teness and accuracy of these technical specifications. However, the information contained
in these technical specifications is subject to change without notice, and does not represent
a commitment on the part of General Electric Canada.
MISCELLANEOUS
Enclosure
Type NEMA 4X steel enclosure; baked enamel; textured white finish
Dimensions
244.5 x 349.3 x 157.7 mm (9 5/8 x 13 3/4 x 3 3/16 in)
Operating Temperature
-40 to +55 °C (-40 to +131 °F) with standard internal heater
Power Supply
• Rated voltage: 90–132 Vac or 180–264 Vac, 47–63 Hz
• Rated power: 145 VA maximum
Standards Met
• CISPR 11: Measurement of radiated and conducted emissions
• IEC 60068-2-1: Environmental testing at cold temperature
• IEC 60068-2-2: Environmental testing at dry heat temperature
• IEC 60255-5: Insulation coordination for measuring relays and
protection equipment
• EN 61000-4-2: ESD immunity
• EN 61000-4-3: Radiated electromagnetic field immunity – radio
frequencies
• EN 61000-4-4: Electrical fast transient/burst immunity
• EN 61000-4-5: Surge immunity
• EN 61000-4-6: Immunity to conducted disturbance induced by
radio-frequency fields
• EN 61000-4-8: Power frequency magnetic field immunity
• EN 61000-4-11: Voltage dips, short interruptions and voltage
variations immunity (applicable for ac power supply only)
• EN 61010-1: Product safety
Safety Conditions
Designed to be safe at least under the following conditions:
• Altitude up to 2,000 m
• Enclosure at temperatures ranging from -40 to +55 °C (-40 to
+131 °F) and at relative humidities of 95 % or less
Weight
• Installed: 6.6 kg (15 lb)
• Shipping: 7.5 kg (17 lb)
Hydran Host Software
Supports all H201T
i
functions plus networking and embedded
software upgrading; available in Microsoft Windows version
Summary of Contents for Hydran 201i
Page 1: ...GE Energy Services Digital Energy Hydran Instruction Manual 201i System ...
Page 6: ...Instruction Manual vi Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 8: ...Instruction Manual viii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 22: ...Instruction Manual xxii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 36: ...Chapter 1 Introduction 1 10 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 114: ...Chapter 5 Before Installation 5 16 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 143: ...Installation Part 17997 Rev 6 March 2011 6 29 Figure 6 9 Installing the CPU Module ...
Page 236: ...Chapter 12 Troubleshooting 12 20 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 244: ...Chapter 13 Maintenance 13 8 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 254: ...Appendix B Mechanical Drawings B 2 Rev 6 March 2011 Part 17997 Figure B 3 1 5 In Adaptor ...
Page 255: ...Hydran 201Ti Intelligent Transmitter Part 17997 Rev 6 March 2011 B 3 Figure B 4 1 In Adaptor ...
Page 284: ...Appendix G Unit Conversions G 2 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 298: ...Appendix I Glossary I 12 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 299: ......