Chapter 12 • Troubleshooting
12-6
Rev. 6, March 2011
Part 17997
•
Alarm cause(s)
: Daily trend below the
DayTrAlr L
alarm set point. Probably indicates
a gas level reading problem.
Proceed as follows:
1.
Verify the daily trend calculated by the Hydran 201T
i
. This value is displayed in the
Main Display mode (see Section 4.2.2 on page 4-4) and also in the
DailyTrend
screen in the
Gas;DailyTrend
submenu (see Section 4.5.2.3 on page 4-17). If this
value seems normal, verify whether the value of the alarm set point is adequate. This
parameter was probably set to a value that is too high.
2.
Verify the gas level measured by the H201T
i
. This value is displayed in the Main
Display mode (see Section 4.2.2 on page 4-4) and also in the
GasLevel
screen in the
Gas;GasLevel
submenu (see Section 4.5.2.1 on page 4-16). If this value seems
normal, verify whether the value of the alarm set point is adequate. This parameter
was probably set to a value that is too high.
3.
Verify whether the breathing membrane of the H201T
i
’s enclosure (item 4 in
Figure 2-1 on page 2-3) and/or the one of the Hydran 201 sensor (see Figure 2-3 on
page 2-6) are obstructed by paint, grease or other products.
4.
Verify whether the valve on which the H201T
i
is installed is open.
5.
Execute the
ForceSensor Test
command in the
Service
submenu to test the operation
of the H201 sensor. A problem may have occurred since the last automatic sensor test
(which is performed the first and fifteenth days of each month at midnight).
12.1.8
DayTrend LL
•
Alarm type
: Fail alarm
•
Non-abbreviated description
: Daily trend Low-Low
•
Priority
: Medium
•
Parameter(s) involved
:
–
DayTrend LL
;
SysOK Relay;FaultTrig.
submenu; Section 4.5.7 on page 4-23
–
DayTrAlr LL
(alarm set point);
Gas;DailyTrend
–
DayTrAlr Delay
;
Gas;DailyTrend
submenu; Section 4.5.2.3 on page 4-17
•
Alarm cause(s)
: Daily trend below the
DayTrAlr LL
alarm set point. Probably indicates
a gas level reading problem.
Summary of Contents for Hydran 201i
Page 1: ...GE Energy Services Digital Energy Hydran Instruction Manual 201i System ...
Page 6: ...Instruction Manual vi Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 8: ...Instruction Manual viii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 22: ...Instruction Manual xxii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 36: ...Chapter 1 Introduction 1 10 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 114: ...Chapter 5 Before Installation 5 16 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 143: ...Installation Part 17997 Rev 6 March 2011 6 29 Figure 6 9 Installing the CPU Module ...
Page 236: ...Chapter 12 Troubleshooting 12 20 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 244: ...Chapter 13 Maintenance 13 8 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 254: ...Appendix B Mechanical Drawings B 2 Rev 6 March 2011 Part 17997 Figure B 3 1 5 In Adaptor ...
Page 255: ...Hydran 201Ti Intelligent Transmitter Part 17997 Rev 6 March 2011 B 3 Figure B 4 1 In Adaptor ...
Page 284: ...Appendix G Unit Conversions G 2 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 298: ...Appendix I Glossary I 12 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 299: ......