CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.5.7
7.
Scroll to
Start Learning
and press
OK
.
8.
Enter the zone number to start with. In this case, enter 9 to program the detectors in zones 9 and 10 and press
OK
.
5.
Tamper the different detectors in sequence. To do this, you activate the sensor’s tamper switch. Table 5-8:
Learning RF sensors
explains how to activate each type of sensor.
9.
Press
##
to leave the programming mode. The
OK to Exit
prompt is displayed. The system now functions as a
normal alarm system. See the
CS5500 LCD Keypad User Manual
for information on arming and disarming
the system.
<
Select Installer Menu>RF Receivers>RF Receiver x>Inputs>Sensor x>Delete to delete an enrolled RF zone.
5.4.3 Configuring receiver features
Configurable receiver features include tampers and communication errors. The following example enables RF
jamming detection on RF receiver 32. RF communication is considered to be jammed when there has been a
jamming signal for more than 30 seconds in a 60 second window.
1.
Navigate with the
µ¶
keys to
RF Receivers
>
RF Receiver 32>Receiver Features
and press
OK
.
2.
Scroll to
Jam Detection>Enabled
and press
OK
.
3.
The keypad beeps once to accept the change and returns to
Jam Detection
.
5.4.4 Setting supervision windows
There are three wireless supervision options: Short Window, Normal Window and Fire Window. PIR and door/
window sensors follow short and normal windows.
•
If a PIR or door/windows sensor does not report within the time specified in Short Window, the system does
not allow the user to arm the system. However, an RF Sensor Lost condition is not reported to the central
station.
•
If a PIR or door/windows sensor does not report within the time specified in Normal Window, an RF Sensor
Lost condition is reported to the central station and a service message is displayed on the keypad.
The short and normal window timers are configured differently according to country and frequency. 868 Mhz
transmitters typically report every 15 minutes while 433 Mhz transmitters typically report every 64 minutes.
I
f you are installing a system in Holland or Belgium, you must set the supervision values to 120 for a long
supervision window. Set the short supervision window in Belgium to 15 and in Holland to 20. Fire transmitter
supervision windows should be set to 240.
When the
Arming with Zone Lost
option is enabled, the user is always allowed to arm the system even if the PIR
or door/window sensor does not report within the short window.
Smoke detectors follow the fire window. 433 Mhz and 868 Mhz smoke sensors report every 64 minutes. Smoke
detectors follow supervision windows only and report to the central station when not reporting within the fire
window.
Table 5-8: Learning RF sensors
Transmitter
Action
Door/Window
Activate the tamper switch by removing the cover.
Door/Window with external contact
Activate the tamper switch by removing the cover.
PIR
Activate the tamper switch by removing the back plate from the PIR.
Fire detector
Press and hold the test button.
Single Button Panic
Press and hold the button.
Keyfobs
Press and hold the arm and disarm buttons together.