CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.2.6
3.
Scroll to
Keyswitch Arming
>
Yes
and press
OK
.
4.
The keypad beeps once to confirm the change and returns to
Keyswitch Arming
.
2.3.3 Programming the keypad sounder
You can specify conditions and/or events that activate the keypad sounder. To configure the sounder, you must
enable the advanced menu. The following example programs the keypad sounder to activate when an expander
trouble condition occurs.
1.
Ensure the advanced menu is enabled.
2.
Navigate with the
µ¶
keys to
Control Panel>Outputs>Keypads
>
Sound On
and press
OK
.
3.
Scroll to
Expander Trouble
>
Enabled
and press
OK
.
4.
The keypad beeps once to confirm the change and returns to
Expander Trouble
.
2.4 Assigning codes
System codes can be either four or six digits long. There are two types of programmable code; an installer code
and a duress code. A duress code disarms the system and activates a duress alarm. This is a silent alarm that
sends a special report to the central station. To program codes, select
Installer Menu>Control Panel>Codes.
2.4.1 Setting up the installer code
An installer code has associated arming options and access rights. To set the authority and access rights, you
must enable the advanced menu. The following example assign partitions 1 and 2 to a new installer code that can
be used only to arm the system.
1.
Ensure the advanced menu is enabled.
2.
Navigate with the
µ¶
keys to
Control Panel>Codes>Installer Code
and press
OK
twice.
3.
Enter the new code and press
OK
.
4.
Enter the new code and press
OK
.
5.
The keypad beeps once to confirm the change and returns to
Code
.
6.
Scroll to
Authority>Arm Only>Yes
and press
OK
.
7.
The keypad beeps once to confirm the change and returns to
Arm Only
.
8.
Navigate with the
µ¶
keys to
Partitions
and press
OK
.
9.
Press the corresponding numerical key to include partitions
1
and
4
and to exclude all other partitions and
press
OK
.
10. The keypad beeps once to confirm the change and returns to
Partitions
.
Duress Code
Code
Arm Only After Closing
Arm Only
Arm/Disarm
Master Code
Bypass Zones
Reports Open/Close
Installer Code
4/6 Digit Codes
Authority
2.3.1
2.3.2
2.3.2.1
2.3.2.2
2.3.2.2.1
2.3.2.2.2
2.3.2.2.3
2.3.2.2.4
2.3.2.2.5
2.3.2.2.6
Partitions
2.3.2.3
2.3.3