CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.9.7
9.2
Call Back Code
A menu option that specifies the code that starts a listen-in session when the
panel is in call back mode. This code can be a maximum of six digits long.
9.3
Line Hold Digit
A menu option that specifies the digit that starts a two-way session when the
control panel is in line hold mode.
9.4
Wrong PIN Digit Entries
A menu option that specifies the maximum number of incorrect digits that can
be entered for call-back and call-in features before the panel is locked out.
9.5
Rings to Answer
A menu option that sets the number of rings that must occur before the panel
answers to start a listen-in session. If the value is 0, the panel or the CS534 will
never react to an incoming phone line and will never pick up the phone line.
Regulations in some countries do not allow a call in from an installer or central
station without approval by the end-user. In this case the Answer U/D Call or
Begin U/D Call menu options should be used instead.
9.6
Timers
A menu entry that groups timer options.
9.6.1
Line Hold Timeout
A menu option that sets the length of time the listen-in module will remain on
the phone line with no activity from the central station. This time can be set
from 30 to 255 seconds. If it does not receive the digit within this time, the
listen-in module disconnects.
9.6.2
New Trip Hangup Time
A menu option that sets the time at which the two-way session timer is reset if
a new event occurs in a partition during a two-way session between the
partition and the central station.
9.6.3
Call Back Window Timer
A menu option that sets the amount of time, in one-minute increments, that the
CS534 listen-in module will wait to call back after an alarm has been reported.
9.6.4
Session Timeout
A menu option that defines how long the listen-in module remains on the
phone line with no activity from the central station.
9.6.5
Indicator-A Time Remaining
A menu option that sets the length of time remaining after indicator “A” is sent
to the central station. The two-way session is terminated after this time if there
is no further activity from the central station. This time can be set between 1
and 255 seconds.
9.6.6
Indicator-B Time Remaining
A menu option that sets the length of time remaining after indicator “B” is sent
to the central station. The two-way session is terminated after this time if there
is no further activity from the central station. This time can be set between 1
and 255 seconds.
9.6.7
Anti-Lock-Up Tone Time
A menu option that sets the interval at which the anti-lock-up tone is sounded
at the central station.
9.7
Volumes
A menu entry that groups options to adjust levels used with the CS534 listen-in
module.
9.7.1
Low Gain Listen In
A menu option that enables the mode in which the central station listens in to
the customer’s premises. This mode is used in environments where
background noise may distort the audio.
9.7.2
High Gain Listen In
A menu option that activates high gain listen-in mode. This is a listen-in mode
that is generally used in environments that produce very low noise.
9.7.3
Speaker
A menu option that sets the volume of the speaker.
9.8
X-10 Devices
A menu entry that groups X-10 device options for the selected listen-in module.
9.8.1.1
Module Number
A menu option that sets the X-10 module number used to identify a particular
X-10 device on the selected module.
A CSx75 bus module number is assigned to each system module. The system
uses this number to identify the module. It is also used to report module
problems (such as tampers and module supervision lost) to the central station.
Location
Term
Definition