Post-Installation Configuration & Checkout
Apollo CNX80 Installation Manual
560-0982-00 Rev D
3-19
Table 3-4 – Description of Input Monitor Items
Display Label
(cyan)
Signal Name
Connector – Pin(s)
Expected Display
(white)
429 IN 1:
429 IN 2:
429 IN 3:
ARINC 429 IN 1
ARINC 429 IN 2
ARINC 429 IN 3
P5-7,27
P5-8,28
P5-9,29
‘FFFFFFFF’ will be displayed if no data has been received.
The hex value of the most recently received label will be
displayed if data is being received.
‘00000000’ will be displayed if data was received, but no data
has been received in the last 5 seconds.
P1-14:
Com Flip Flop In
P1-14
‘0’ in input is open
‘1’ if input is grounded
P1-15:
UP Discrete In
P1-15
‘0’ in input is open
‘1’ if input is grounded
P1-33:
DOWN Discrete In
P1-33
‘0’ in input is open
‘1’ if input is grounded
P1-34:
VOR Flip Flop In
P1-34
‘0’ in input is open
‘1’ if input is grounded
P5-36:
OBI Select In
P5-36
‘0’ in input is open
‘1’ if input is grounded
P5-56: RESERVED
P5-56
‘0’ in input is open
‘1’ if input is > 9 VDC
P5-57:
Heading Valid In
P5-57
‘0’ in input is open
‘1’ if input is > 9 VDC
P5-72: RESERVED
P5-72
‘0’ in input is open
‘1’ if input is grounded
P5-73: RESERVED
P5-73
‘0’ in input is open
‘1’ if input is grounded
P5-74: RESERVED
P5-74
‘0’ in input is open
‘1’ if input is grounded
P5-75: RESERVED
P5-75
‘0’ in input is open
‘1’ if input is grounded
P5-76: Suspend
In P5-76
‘0’ in input is open
‘1’ if input is grounded
P5-77:
Audio Inhibit In
P5-77
‘0’ in input is open
‘1’ if input is grounded
P5-78: RESERVED
P5-78
‘0’ in input is open
‘1’ if input is grounded
P4-4: Com
PTT
P4-4
‘0’ in input is open
‘1’ if input is grounded
CDI SEL:
Main CDI Select In
P7-8
Normally a ‘-‘ is displayed. When the input is actuated a ‘T’
will be displayed for approximately 1 sec.
232-1:
232-2:
232-3:
422-4:
232-5:
232-6:
232-7:
232-8:
RS232 Port 1 In
RS232 Port 2 In
RS232 Port 3 In
RS422 Port 4 In
RS232 Port 5 In
RS232 Port 6 In
RS232 Port 7 In
RS232 Port 8 In
P1-4,23
P1-3,21
P1-7,25
P1-11,26
P5-1,41
P5-2,42
P5-10,44
P5-30,44
‘FF’ will be displayed if no data has been received.
The hex value of the most recently received data will be
displayed if data is being received.
‘00’ will be displayed if data was received, but no data has
been received in the last 5 seconds.
SYNCHRO HDG:
Synchro Heading
P5-18,19,38
If the synchro valid discrete is INVALID or the 26VAC,
400Hz reference is not present, ‘---‘ will be displayed;
otherwise, the angle of the synchro heading input will be
displayed.
BARO:
Baro Correction Pot
P5-13,33,53
The value of the baro potentiometer input will be displayed.
‘0’ will be displayed if input is open, or if the baro pot input
has not been properly calibrated.
26VAC
26 VAC Reference
P5-20,39
The voltage and frequency of the 26VAC, 400Hz input will be
displayed. If this input is not connected, or if the voltage is
below 1VAC, ‘---‘ will be displayed.
Summary of Contents for Apollo CNX80
Page 1: ...Apollo CNX80 Installation Manual September 2003 560 0982 00 Rev D...
Page 10: ...Table of Contents viii 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 114: ...Periodic Maintenance 6 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 134: ...Appendix D Interconnect Diagrams D 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 167: ......
Page 168: ......