Post-Installation Configuration & Checkout
Apollo CNX80 Installation Manual
560-0982-00 Rev D
3-31
3.4 D
ATABASE
C
HECK
Check the database to ensure it is current. The database information is displayed at startup. To check the
database:
1.
Turn off the CNX80 and then turn it on. The CNX80 will go through its normal start-up sequence.
2.
Wait for the database page to be displayed.
3.
Verify that the database is not expired (the expiration date will be displayed in green text if the
database is current, and yellow text if it has expired).
If the database card has to be reprogrammed with a new revision, remove and replace the database card as
described in the following section.
3.4.1 D
ATA
C
ARD
R
EPLACEMENT
CAUTION
Handle the data card carefully. Do not touch the connector edge of the data card.
Do
not insert or remove the data card within 10 seconds after the CNX80 is turned on.
To replace the data card do the following:
1.
Ensure that the CNX80 is turned off.
2.
Press the data card ejector to eject the card and remove the data card. Gently pull the card straight out
of the slot.
3.
With the label facing left, insert the new data card by pushing the card straight into the slot and press
firmly into place. When fully inserted, the ejector button will be flush with the top of the data card.
Summary of Contents for Apollo CNX80
Page 1: ...Apollo CNX80 Installation Manual September 2003 560 0982 00 Rev D...
Page 10: ...Table of Contents viii 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 114: ...Periodic Maintenance 6 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 134: ...Appendix D Interconnect Diagrams D 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 167: ......
Page 168: ......