Post-Installation Configuration & Checkout
Apollo CNX80 Installation Manual
560-0982-00 Rev D
3-17
Figure 3-18 - Interface Monitor Function Display - Page 1
This page displays activity on each of the ARINC 429 inputs, and the state of each of the discrete inputs.
Press the
NEXT
line select key to show the next page, which is shown in Figure 3-19.
Figure 3-19 - Interface Monitor Function Display - Page 2
This page displays activity on each of the serial inputs, and allows the serial data that is being received on a
particular input to be monitored. Turn the large, outer knob to select the input to be monitored. The
currently selected serial channel is indicated with a green background. The window on the lower half of the
screen displays the last 100 characters that have been received. To stop the update of the data in the
window press the
PAUSE
line select key, which will then become the
RUN
line select key. To start the
update of the data press the
RUN
line select key.
Press the
NEXT
line select key to show the next page, which is shown in Figure 3-20.
Summary of Contents for Apollo CNX80
Page 1: ...Apollo CNX80 Installation Manual September 2003 560 0982 00 Rev D...
Page 10: ...Table of Contents viii 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 114: ...Periodic Maintenance 6 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 134: ...Appendix D Interconnect Diagrams D 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 167: ......