Installation
Procedures
Apollo CNX80 Installation Manual
560-0982-00 Rev D
2-13
Figure 2-5 - Cam Lock Positioning
2.6.3 U
NIT
R
EMOVAL
To remove the unit from the mounting frame, turn the screw counter-clockwise with the hex driver to
unscrew the cam lock mechanism. The unit will begin to pull away from the mounting tube. Turn the screw
until slight resistance is felt and then pull the unit from the frame.
Do not exert excessive turning force at
the end of the cam lock travel or the unit may be damaged.
With the cam lock fully disengaged, pull the
unit straight out while holding onto the sides of the bezel. It is not recommended that you pull the unit out
by the rotary knobs. No special extraction tools are required if the mounting tube is properly installed.
2.6.4 U
NIT
R
EPLACEMENT
Whenever the CNX80 is removed and reinstalled, verify that the CNX80 unit power-up self-test sequence
is successfully completed and no failure messages are annunciated. If the unit was serviced or if a different
unit is being installed, accomplish the setup and configuration procedures defined in 3.2 prior to verifying
that the CNX80 unit power-up self-test sequence is successfully completed and no failure messages are
annunciated. The setup items for a particular installation should have been previously recorded on a Post-
Installation Checkout Log that was completed upon initial installation (refer to Table 3-5).
Summary of Contents for Apollo CNX80
Page 1: ...Apollo CNX80 Installation Manual September 2003 560 0982 00 Rev D...
Page 10: ...Table of Contents viii 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 114: ...Periodic Maintenance 6 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 134: ...Appendix D Interconnect Diagrams D 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 167: ......
Page 168: ......