Post-Installation Configuration & Checkout
Apollo CNX80 Installation Manual
560-0982-00 Rev D
3-13
NOTE
For some HSI’s the glideslope indicator may not be visible unless it is receiving a valid
signal from the localizer (ILS Energize is present). If this is the case, leave these signals
set to VALID following completion of the FLAG TEST in order to see the glideslope
indicator.
Press the
TEST
or
BACK
smart key to return to the Ground Maintenance Test menu.
3.3.1.1.4 Annunciator Lamp Output Test
The LAMP OUTPUT TEST page allows testing of each of the annunciator outputs. While on the TEST
menu page, press the
LAMP OUTPUT TEST
line select key to display the LAMP OUTPUT Page. The
LAMP OUTPUT page is shown in Figure 3-14.
Figure 3-14 - Lamp Output Test
Turn the large, outer knob to select the annunciator output to be tested. The currently selected lamp output
is indicated with a white box around it. Turn the small, inner knob to change the setting of the selected
annunciator lamp output – a green background indicates that the annunciator output is ON (grounded), and
a black background indicates that the annunciator output is OFF (open). Details for each annunciator lamp
output that can be tested are found in Table 3-3.
Summary of Contents for Apollo CNX80
Page 1: ...Apollo CNX80 Installation Manual September 2003 560 0982 00 Rev D...
Page 10: ...Table of Contents viii 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 114: ...Periodic Maintenance 6 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 134: ...Appendix D Interconnect Diagrams D 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Page 167: ......
Page 168: ......