User Guide
EdgeLens | INT10G8XX56 | 4.22.1
2. Select NTP timing.
3. Enter the IPv4 or IPv6 Address.
4. Select Authenticate, Symmetric.
5. Select Encryption Type, (MD5, SHA1, SHA224, SHA256, SHA384, SHA512)
6. Enter the Key Number.
7. Enter the Key.
8. Select Save.
The NTP Status will display “syncing”. Eventually the NTP Status will display “Synced”.
This can take several minutes.
9. Select Cancel to return to the Date & Time Settings panel.
Syslog
The system supports an IPv4 or IPv6 address for Syslog. If IPv4 is desired, then an IPv4
management interface must be assigned. If IPv6 is desired, then an IPv6 management interface
must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned
simultaneously.
1. Select Syslog.
The Syslog Configuration panel will be displayed.
2. Select Edit Settings.
3. Select Enable Syslog Config.
4. Enable Unit ID, (optional).
5. Enter the Unit ID, (optional).
6. Enter the IPv4 or IPv6 Address.
7. Enter the desired UDP Port Number or use the default, 514.
8. Select Save.
9. Select Cancel to return the Syslog Configuration panel.
Syslog Test
1. Select Syslog Test.
The GUI message will be displayed,”Syslog Test Successful!”.
2. Verify the Syslog Test Message on the Syslog server.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
21