User Guide
EdgeLens | INT10G8XX56 | 4.22.1
7. Revertive
If enabled and the primary inline appliance port(s) fail, loss of link or
heartbeats, the system will switch to the secondary inline appliance.
When the issue with the primary inline appliance is resolved, has link and
heartbeats. The traffic will automatically revert back to the primary inline
appliance. This option also affects the switching from bypass to inline. If
disabled, the system is designed to switch from bypass to the secondary inline
appliance. If the primary inline appliance restores first, has link and heartbeats,
a manual switch to the primary inline appliance is required. If enabled and the
primary inline appliance restores first, the system will switch from bypass to the
primary inline appliance.
8. Select Accept to save updates. Save must additionally be selected on the Bypass Taps panel.
9. Select Cancel to return the Bypass Taps panel.
Switch To Primary
1. Select to manually switch the traffic from the secondary inline appliance to the primary inline appliance.
Monitor Ports
Monitor ports may be added to any tap. Each tap may have up to two monitor ports per network port, total
of four monitor ports per tap. The monitor ports may be added to monitor the ingress traffic or egress
traffic.
1. Create a monitor port by placing the cursor on the desired port, shaded gray above the tap. Press the
left mouse button and hold to select the port. Drag the port to the desired network port. The default of
any monitor port is ingress. Change the monitor port traffic by placing the cursor on the ingress panel
and press the left mouse button. Additional monitor ports may be added using the same procedure.
2. Select Save to save updates.
3. Select Cancel to return the Bypass Taps panel.
Figure 16 Primary-Secondary Tap Mode (Monitor Port)