User Guide
EdgeLens | INT10G8XX56 | 4.22.1
2. Select Edit Tap Settings.
The Configure Inline Appliance panel will be displayed.
3. Select the Tap Mode.
Active
Allows the tap to automatically switch from inline to bypass if an issue occurs
with the inline appliance port(s), loss of link or heartbeats, defined by the bypass
threshold value, 1-4. When the issue with the inline appliance port(s) is resolved,
have link and heartbeats, the tap will automatically switch back to inline.
Figure 18 Load Balance Tap Mode (Inline)
Figure 19 Load Balance Tap Mode (Bypass, Bypass Threshold=2)
Force Bypass If selected, the tap will switch the traffic between the network ports with no
regard for the inline appliance ports, link or heartbeats. Typically used during
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
39