User Guide
EdgeLens | INT10G8XX56 | 4.22.1
5. Select Configure.
The Configure panel will be displayed.
6. Select VXLAN TX Only
7. Enter the Tunnel IP Address, (VXLAN Header SIP).
8. Enter the Next Hop IP Address, (VXLAN Header DIP).
9. Enter the Next Hop MAC Address, (VXLAN Header DMAC).
10. Enter the VNID, (1-16777215).
The default UDP destination port is 4789.
11. Select Advanced to modify the UDP destination port, (1-65535).
The default VXLAN Header SMAC is automatically defined by the system. There are five
predefined SMACs.
12. Select Advanced to select an alternative SMAC or to manually enter the SMAC.
13. Select Advanced to add a VLAN ID to the VXLAN Header, optional, (1-4095).
14. Select Set.
15. Select Cancel to disregard.
16. Select Save.
The vxlan-tx-only tunnel will be displayed on the Tunnels panel.
17. The tunnel may be deleted by selecting the Red X.
18. Select OK.
Decapsulate VXLAN Packets (VXLAN RX Only)
When the VXLAN header is decapsulated from a packet, the VXLAN header segments are removed
as shown below.
VXLAN Encapsulated Packet
VXLAN Decapsulated Packet