SER
VICING
121
PULSE Installation, Commissioning and Servicing Manual - Revision 19
23.3 Blending Manifold
The blending manifold has 3 proportional valves attached with two non return valves. The
two “component” fuels are fed into the manifold and channelled proportionally into the
centre of the manifold to make the blended fuel.
Figure 49� Blending Manifold Assembly
23.4 WIRING
This section describes the wiring and cable connections specific to the blending dispenser.
Additional components used are:
−
a second Integrated Stack Controller located in the head
−
a second Multiplexer located in the hydraulic cabinet
−
a second Barrier located in the head
−
an Auxiliary Power Module
The Multiplexer Board for a particular side is located on the right.
Compared to the wiring in a conventional dispenser, the
Auxiliary Power Module is wired
in a similar way, whereas the Multiplexer Board is slightly different.
23.5 Stack Controllers
Each Integrated Stack Controller has valve sockets marked P28-P22 from left.
Note
:
FRONT
solenoid valves connect to Stack Controller 1000, (top)
REAR
solenoid valves connect to Stack Controller 1100, (bottom).
non-return valve
blending manifold
solenoid valves
seal