SER
VICING
102
PULSE Installation, Commissioning and Servicing Manual - Revision 19
15.22 Firmware - FIRMWARE
The following actions are possible regarding the firmware:
y
viewing of the installed firmware version number(s);
y
upgrading firmware, and
y
rollback to previously installed firmware, provided that the previous version is still
available on the module.
Note that the rollback option is not available on a Central Controller.
STK1
C
L
12001
FIRMWARE
The display will show
FIRMWARE
in the Dollars display. The first available
price display will show the module hardware address (ID), according to
the table below. The installed firmware version number (e.g.
12001
) is
shown in the Litres display.
Use the cursor keys
4
and
6
to navigate left and right to view the different firmware
versions installed. From this point, either an upgrade or a rollback can be actioned.
Note that if two or more of the same type of module are present with the same firmware
version installed, the display will appear not to change other than the ID in the Price
window.
Module Name
ID
Stack Controller
STK1; STK2
User Interface
UI2000; UI2100; UI3000; UI3100
Central Controller
CC
$
15.21.6 SYSLOGS
Creates SYSLOGS when
F
is pressed.
Press the
F
button to start creation of the logs. The operator will
see SYSLOGS “CREATING” and when it is finished SYSLOGS “OK”.
Press
to return to the main menu. Before removing the SD Card
from the pump either lock it or power down the unit.
The extra logs copied over can be found in the “syslog” folder on the
dispenser’s SD Card.
C
L
CREATE
SYSLOGS
$
C
L
CREATING
SYSLOGS
$
C
L
OK
SYSLOGS
$
Version 1.20